Devices and technology
Laboratory equipment and instrumentation for experimental use
- Workplace of chemical measures
- Workplace of specialized protection
- Workplace of radiation countermeasures
- Workspace of fire causes investigation
Workplace of chemical measures
Workplace of chemical measures
Apparatus, technology |
Description |
---|---|
Portable Raman spectrometer |
The device allows identification of completely unknown substances directly in the field |
SIGIS 2 remote detector |
It is designed to identify clouds of combat and other dangerous chemicals in the air from great distances from the site of the outflow (up to 5 km). Hazardous substances are measured non-contact over long distances, outside the contaminated area, which completely eliminates risk of inhalation exposure of an operator and eliminates contamination of vehicles, property and decontamination, need for individual protection, etc. The device does not measure air at one point, but detects whole cloud of leaked hazardous substances, provides information on its spread and development. |
Liquid chromatograph with mass detector |
Device is mainly used for assessing foam-forming mixtures for extinguishing offered by the Fire Rescue Service of the Czech Republic |
Room for non-destructive examination by X-rays |
It is a stationary X-ray cabin with two small X-ray sources (120kV and 160kV) |
SYCOS KDP devices and Q-RAE detector |
With them it is possible to measure dynamic sorption capacities (DSC) not only for gaseous but also liquid substances with low boiling point |
Portable FTIR spectrometer |
The device allows identification of completely unknown substances directly in the field |
Portable mass spectrometer |
It is designed for highly sensitive field identification of substances in the air and swabs from surfaces |
Hand X-ray fluorescence analyser |
It is used for fast non-destructive analysis of elemental composition of samples in the field |
Detector of ultra-trace concentrations of explosives |
The device is designed for fast field detection of very low concentrations of explosives and classification of detected explosive into appropriate group |
Gas chromatograph with mass detector |
The system is designed for identification and determination of organic substances in the air, water, soil and other matrices |
Inductively coupled plasma mass spectrometer |
It enables multi-component determination of elements in drinking, surface and wastewater |
Workplace of specialized protection
Workplace of specialized protection
Apparatus, technology |
Description |
---|---|
BIOBOX and photoacoustic IR spectrometer |
These devices are the basis for measuring penetration into the personal protective equipment (PPE) and with other devices it is possible to measure the tightness of personal protective equipment. |
Laboratory tract for PPE |
Possibility to perform DSC measurements, PPE tightness and other parameters |
KOMPIO |
Special test chamber to verify tightness of protective equipment (protective masks, protective helmets and protective clothing) |
Workplace of radiation countermeasures
Workplace of radiation countermeasures
Apparatus, technology |
Description |
---|---|
Emergency radiometer DC-3H-08 |
Hand radiometer for measuring dose rate of gamma radiation and surface contamination by particles emitting beta and gamma radiation |
Portable gamma spectrometer InSpektor 1000 |
Portable semiconductor HPGe detector for identification and estimation of gamma-emitting radionuclide activities |
FALCON 5000 portable gamma spectrometer |
Portable semiconductor HPGe detector for measuring gamma radiation spectra. The Genie 2000 program enables identification of radionuclides and detailed analysis of spectra, including isotopic composition. |
Gamma spektrometr BEGe (broad energy germanium detector) BE 5030 |
Thanks to its high resolution, it enables detailed analyses even for complex samples containing a mixture of different radionuclides. Evaluation is performed in the Genie 2000 program. |
Tri-Carb 4910TR liquid scintillation analyser |
In particular, analysis of liquid samples emitting alpha (0-8 MeV) and beta (0-2 MeV) radiation with possibility of separation of alpha and beta radiation. |
Alpha, beta automaton EMS 3 |
Measurement of alpha and beta activity of solid samples, or evaporators in determination of alpha and beta and activity of liquid samples. |
FHT 752 detector |
Measurement of neutron dose rate |
MOB-Dose |
Simultaneous measurement and recording of dose rate of gamma and GPS radiation. Monitoring of large areas. |
Set of portable frame, portal gamma radiation monitor |
To control people and equipment contamination when leaving the emergency planning zone in the event of a radiation accident at a nuclear power plant |
Workspace of fire causes investigation
Workspace of fire causes investigation
Apparatus, technology |
Description |
---|---|
Diffusion gas detector GAS Alert MICRO 5 |
Detectors 02, LEL, CO / H2S, HCN, explosive gases |
Diffusion gas detector GAS Alert MICRO IR 5 |
O2, LEL, CO2, NH3 detectors |
Diffusion gas detector Drager X-am 5100 |
HC1 sensor |
FLUKE Ti400 thermal imaging camera |
Thermal camera with radiometric video output with a temperature range of -20 to +1200 ° C |
FLUKE Ti32 thermal imaging camera |
Thermal imager with a temperature range of 650 ° C |
MULTI FLASH |
Apparatus for determining flash and fire point |
CLASIC CLARE 4.0 |
Apparatus for determining ignition temperatures of liquid vapours |
FARO FOCUS X130 3D laser scanner |
Spatial laser scanner for fire place digitization |
Spherical camera iSTAR Fusion |
Equipment for fire place documentation |
Automatic panoramic head for Gigapan Epic PRO spherical images |
Apparatus for better fire place documentation |
Cabin X-ray system |
Non-destructive samples examination |